HOME > Support >Developer >
Windows SDK Download
2019 年 05 月 20 日
SDK Update History
There are many software using the QHYCCD SDK to connect QHY Camera. When the SDK updated, the software maybe not get updated. You can download this file and copy it to the software folder and replace the old more to get your software has the lastest features of QHYCCD.

Update Method
You can update the qhyccd.dll by replacing the original qhyccd.dll in the application software folder.
SharpCAP
You can replace the 32bit qhyccd.dll in the sharcap folder.
EZCAP_QT
You can replace the 32bit qhyccd.dll in EZCAP_QT folder.
ASCOM
Since the old ascom camera driver installation put the QHYCCD.DLL to the windows/SysWow64 or windows/system32. And the recently ascom camera driver put the QHYCCD.DLL into the programe(x86)/common/ascom/camera.  We recommand to delete the QHYCCD in windows/SysWow64 or windows/system32 and put the new QHYCCD.DLL to the programe(x86)/common/ascom/camera folder.
FireCapture
You can replace the 64bit qhyccd.dll in FireCapture 64bit folder  or 32bit qhyccd.dll in FireCapture 32bit folder.
Genika
Only 64bit Genika is under maintain and support QHYCCD. You can find the Genika in Programme and find the 64bit Genika folder.And replace the qhyccd.dll with the 64bit qhyccd_x64.dll (delete qhyccd.dll, rename the qhyccd_x64.dll to qhyccd.dll)

Version Record   The Red font is a description of important BUG fixes, green font is a description of existing problems, and black font is a new addition.
V2019.05.20.0 WINDOWS X86_X64 qhyccd_V20190520_0
update record:
1. Solve the problem that the demo program can not compile because the header file contains errors.
2. This version mainly collates and optimizes the code.
Note:
1.This version does not support QHY8 QHY8Pro QHY5 QHY12 cameras at present.
2.This version of the change requires the latest driver,if your driver version isn't newest,it will popup a dialog to ask you to install the newest driver.
3. Update record information includes QHYCCD SDK library and TheSkyX plug-in under all operating systems.
 

V2019.05.03.0 WINDOWS X86_X64 qhyccd_V20190503_0
update record:
1. Modified the problem that QHY42PRO does not map under 16 bits in the latest version of SHARP RPCAP that supports ReadMode.
2. The exposure time of series A cameras of modified WINDOWS platform QHYCCD SDK is longer than 3 seconds, which will lead to the failure of reading single frame image.
Note:
1.This version does not support QHY8 QHY8Pro QHY5 QHY12 cameras at present.
2.This version of the change requires the latest driver,if your driver version isn't newest,it will popup a dialog to ask you to install the newest driver.
3. Update record information includes QHYCCD SDK library and TheSkyX plug-in under all operating systems.
 

V2019.04.25.0 WINDOWS X86_X64 qhyccd_V20190425_0
update record:
1. Perfect QHY6060 camera.
2. Increase QHY411 new camera support.
Note:
1.This version does not support QHY8 QHY8Pro QHY5 QHY12 cameras at present.
2.This version of the change requires the latest driver,if your driver version isn't newest,it will popup a dialog to ask you to install the newest driver.
3. Update record information includes QHYCCD SDK library and TheSkyX plug-in under all operating systems.
 
V2019.04.11.0 WINDOWS X86_X64 qhyccd_V20190411_0
update record:
1. Fixed the problem of SDK runaway in single frame capture of 5III series cameras.
2. Repair the inaccurate gain setting of QHY163.
Note:
1.This version does not support QHY8 QHY8Pro QHY5 QHY8L QHY12 cameras at present.
2.This version of the change requires the latest driver,if your driver version isn't newest,it will popup a dialog to ask you to install the newest driver.
3. Update record information includes QHYCCD SDK library and TheSkyX plug-in under all operating systems.
 
V2019.04.08.0 WINDOWS X86_X64 qhyccd_V20190408_0
update record:
1. Updated a number of firmware, mainly Series A, are updated to the latest version.
2. Some errors in 85-qhyccd. rules have been corrected, mainly in Series A.
3. Added readMode function of QHY2020
4. Increase QHY6060 Camera Support
5. Repaired the QHY5II camera. Modifying parameters such as exposure time in SC will lead to crash problems, and shooting in MAXIMDL will lead to crash problems.
6.
This version has the problem of single frame capture SDK runaway for 5III series cameras.
Note:
1.This version does not support QHY8 QHY8Pro QHY5 cameras at present.
2.This version of the change requires the latest driver,if your driver version isn't newest,it will popup a dialog to ask you to install the newest driver.
3. Update record information includes QHYCCD SDK library and TheSkyX plug-in under all operating systems.

V2019.03.25.0 WINDOWS X86_X64 qhyccd_V20190325_0
update record:
1. Repair the abnormal readout of Series A cameras. You can only read one, and then shoot it again.
2. Fix the problem of firmware download of QHY294C, QHY16830A and QHY09000A in Linux and rpi3 systems.
3 Fix QHY09000A firmware download problem in MacOS and Android system.
4. Increase the excuse function of callback function mode.
 
Note:
1.This version does not support QHY8 QHY8Pro QHY5 cameras at present.
2.This version of the change requires the latest driver,if your driver version isn't newest,it will popup a dialog to ask you to install the newest driver.
3. Update record information includes QHYCCD SDK library and TheSkyX plug-in under all operating systems.
 

V2019.03.14.0 WINDOWS X86_X64 qhyccd_V20190314_0
update record:
1. Fixed the case that QHY294C has a single frame mode, and the image occasionally moves 2 pixels to the right, and the corresponding image start position was modified.
2. Repair BUG of ROI function of QHY8L and QHY9.
3. Repair the problem that some cameras lack exposure or the exposure step is incorrect.
4. Repair the problems in error handling of vendRXD, TXD, RXD_EX and TXD_EX of QHYCAM.CPP.
5. Realize GetQHYCCD Exposure Remaining function to get the remaining percentage of exposure time.
6. Correct BUG implied in firmware function module downloaded from memory.
7. Optimizing image memory allocation in linux, MacOS and rpi3 systems.
8. Increase the function GetQHYCCDBeforeOpenParam to get the step size and interval of gain and offset before opening the camera.
9.x2 increases the range size of gain and offset of the camera, and refreshes the window data to the parameters of the camera after selecting different cameras in the drop-down box.
10. Add a multi-check box in the settings window to select whether qhy10 and qhy12 need 90 degrees of rotation.
11. Modify QHY5III 224C single frame mode to turn on AMPV function by default.
12. Add Gain and Offset intervals to the X2 plug-in settings window, and add the set cameras for guiding stars or shooting cameras.
13. Correct the problem that QHY8PRO, QHY9T, QHY10, QHY11, QHY12, QHY15, QHY16, QHY21, QHY22, QHY23 camera acquisition function return does not support cooler.
Note:
1.This version does not support QHY8 QHY8Pro QHY5 cameras at present.
2.This version of the change requires the latest driver,if your driver version isn't newest,it will popup a dialog to ask you to install the newest driver.
3. Update record information includes QHYCCD SDK library and TheSkyX plug-in under all operating systems.
 


V2019.02.21.0 WINDOWS X86_X64 qhyccd_V20190228_0
update record:
1. Repair QHY178C in single frame mode, direct shooting will appear abnormal image, local noise BUG.
2. Fixed the blocked BUG in ROI mode of QHY5II.
3. Repair the BUG lost by WINUSB camera after scanning again in ASCOM.
4. Repaired the ROI of QHY8L, modified the ROI and shot the second BUG that would collapse.
5. Adding IsQHYCCDControlAvailable function, we can know whether the camera supports single-frame mode and continuous mode by calling. (See SDK development manual for more information on usage.)
6. In V4.0.14 version, QHY178 needs the second frame exposure time to correct the BUG.
7. Add downfirmware. CPP to download firmware from memory.
8. Correct 163M camera gain value to return incorrect bug.
9. Correct the bug that the gain value returns to 1 in the single frame mode of 168C camera.
10. Fix QHY183 in V4.0.14 in continuous mode, 8BIT and 16BIT do not map the problem.
11. Fixed a BUG returned from the judgement involving the connection of the filter wheel.
12. In the single frame mode of QHY294C, the image occasionally shifts 2 pixels to the right, which is repaired, and the corresponding starting position of the image is modified accordingly.
13. Fix the bug that the 5III 290C M camera falls into a dead cycle when acquiring single frame and active frame images in Linux, RPI3 and MacOS (the reason is that the firmware is correct after replacing the new firmware).
14. Adding the save function of X2 camera after selection.
15. Add functions to get and print SDK version number and firmware version number in testapp.
16. Open the function of downloading firmware from memory in LINUX and RPI3 systems.
 
Note:
1.This version does not support QHY8 QHY8Pro QHY5 cameras at present.
2.This version of the change requires the latest driver,if your driver version isn't newest,it will popup a dialog to ask you to install the newest driver.
3. Update record information includes QHYCCD SDK library and TheSkyX plug-in under all operating systems.
 

V2019.02.21.0 WINDOWS X86_X64 qhyccd_V20190221_0
update record:
1.Fixed some of the camera abnormalities in the previous version;
Note:
1.This version does not support QHY8 QHY8Pro QHY5 cameras at present.
2.This version of the change requires the latest driver,if your driver version isn't newest,it will popup a dialog to ask you to install the newest driver.
3.Due to used some older code by mistake, In this version. The QHY294C has a bug that show overscan area in LiveVideo Mode(like in Sharpcap) and the overscan remove function is not work in single frame mode (like in ASCOM) .We will fix this in next version.

V2019.02.11.0 WINDOWS X86_X64 qhyccd_V20190211_0
update record:
1.Fixed the BUG of no image captured by QHY2020 camera in live frame.;
2.Complete the missing header files for QHYCCD SDK secondary development;
 
 
Note:
1.This version does not support QHY8 QHY8Pro QHY5 cameras at present.
2.This version of the change requires the latest driver,if your driver version isn't newest,it will popup a dialog to ask you to install the newest driver.
3.Due to used some older code by mistake, In this version. The QHY294C has a bug that show overscan area in LiveVideo Mode(like in Sharpcap) and the overscan remove function is not work in single frame mode (like in ASCOM) .We will fix this in next version.

V2019.01.22.0 WINDOWS X86_X64 qhyccd_V20190122_0
update record:
1.This version of QHYCCD SDK has made great changes and optimizations from the structure, and can access and process multiple (theoretically up to 18) QHYCCD cameras;
2.Added support for cameras QHY294, QHY550, QHY2020, QHY42, QHY4040,QHY42PRO;
3.Fixed the BUG of no image captured by QHY183M camera in single frame.;
4.Fixed the BUG of incorrect live mode image of QHY178 camera;
5.
Fixed the BUG that the same target temperature could not be refrigerated after the camera closed the refrigeration.
Note:
1.This version does not support QHY8 QHY8Pro QHY5 cameras at present.
2.This version of the change requires the latest driver,if your driver version isn't newest,it will popup a dialog to ask you to install the newest driver.

V2018.05.02.0 WINDOWS X86_X64 qhyccd_V20180502_0.zip
update record:
1.Party cameras have issue with  auto exposure/gain/color balance mode when get single frame,now we has fixed them;
2.Removed dependence of pssdk.dll,but it still contain tbb.dll and ftd2xx.dll;
Note:This version of the change requires the latest driver,if your driver version isn't newest,it will popup a dialog to ask you to install the newest driver.

V2018.04.24.0 WINDOWS X86_X64 qhyccd_V20180424_0.zip
update record:
1.Fixed SDK version error issue;
2.Added necessary librarys(pssdk.dll&pssdk_x64 and tbb.dll&tbb_x64.dll and ftd2xx.dll&ftd2xx_x64.dll);
Note:This version of the change requires the latest driver,if your driver version isn't newest,it will popup a dialog to ask you to install the newest driver.

V2018.04.13.0 WINDOWS X86_X64 qhyccd_V20180413_0.zip
update record:
1.Added partly support for qhy4040 and qhy294(alpha version);
2.Improved the QHY183C/M,QHY128,QHY163,QHY168,QHY174,QHY1178,QHY224,QHY247,QHY290,QHY367,QHY42 stability and avoid occasionally crash issue in single mode(USB2.0);
3.Fixed the issue about MINICAM5F&PoleMaster crash;
4.Added the offset setup for QHY5L-II-C/M&MINICAM5F&PoleMaster(range is 1~512);
5.Fixed QHY5L-II camera crash issue when adjust exposure time in long expose;
6.Added Amplifier glow control control for QHY42;
7.Fixed  183C/M the problem of insufficient full well at lowest gain;
8.Added DefaultGain  DefaultOffset OutputDataActualBits  OutputDataAlignment in GetQHYCCDParam;
Note:This version of the change requires the latest driver,if your driver version isn't newest,it will popup a dialog to ask you to install the newest driver.

V2017.12.21.0 WINDOWS X86_X64  qhyccd_V20171221_0.zip
update record:
1.Fixed the bug that cause the QHY5L-II in live video mode image slightly shifit when in high frame rate(usb bandwidth value is small, eg. >20FPS. This bug affect the driver version from 2017.08.14 to 2017.11.09;
2.Improved the QHY5L-II stability and avoid the hang happen (this bug effect the driver from 2017.05.29 to 2017.11.09;
3.Improved the gain setting range for QHY5L-II-M and QHY5L-II-C. (expanding the actual gain range but reduce the gain steps);
4.Fxied the QHY247C,QHY168C,QHY367C,QHY128C etc the overscan area definitation in EZCAP_QT and the effective image definitation in EZCAP_QT;
5.Fixed the bug that QHY5III series does not suppot CancelExopsing and CancelExposuringAndReadout;
6.Add QHY42 support;
7.Add QHY183M support.

V2017.11.09.0 WINDOWS X86_X64  qhyccd_V20171109_0.zip
update record:
1.Fixed the overscan remove area define error in the EZCAP_QT for QHY168C,QHY247C issue;
2.Reduce about 12rows for QHY168 fullframe readout image because it is exceed the effeictive image area and the data is a fixed white value . Now it is 5040*3346, before it is 5050*3358. (The overscan remove mode resolution is not changed);
3.Increase the USB traffic limiation in the QHY247C when in USB2.0 mode. To avoid the DDR buffer get full and the image become more and more slow and then hang.

V2017.10.25.0 WINDOWS X86_X64   qhyccd_V20171025_0.zip
update record:
1.Fixed previous version issue that QHY183 has problem in EZCAP_QT;
2.Force the QHY183C usb traffic to zero when in singleframe mode to minumum the ampglow during readout;
3.Add the support for IMG2PRO;
4. Adjust the usb packet size for QHY21,22,23 and reduce the USB pause dot when CPU busying.
An known bug in this version:
1.QHY247C under USB2.0, when in SharpCAP will be hang. The reason is the USB traffic is too small. We will increase this in next version. This issue does not effect the USB3.0 in SharpCAP, also does not effect the single frame mode like ASCOM / EZCAP_QT;
2. In QHY163 there is some blank lines appear in the full image and in the image with overscan remove mode. We will fix this problem in next version.

V2017.09.26.0 WINDOWS X86_X64   qhyccd_V20170926_0.zip
update record:
1.in previous version (20170926), the QHY183C works nice in ASCOM but it has a problem in EZCAP_QT when exposure is longer than some seconds. This version fixed it.
2. Add the full support for QHY09000A.
An known bug in this version:
1.QHY183C have bug under EZCAP_QT when use this verison. When exposure is a little longer the image will has a wrong part on top of it.

V2017.09.19.0 WINDOWS X86_X64   qhyccd_V20170919_0.zip
update record:
1.In previous version(20170910) the QHYCCD A series support has some problem since an unexpected modification. Now we fixed it;
2.Add the baisc support for QHY09000A.

V2017.09.10.0 WINDOWS X86_X64   qhyccd_V20170910_0.zip
update record:
1.Fixed the QHY367 image shift issue in single frame when do continous capture;
2.Improved the QHY183 USB transfer when connected to some computer.Fixed the QHY183C roi problem when in some small roi;
3. Improved the QHY178 single frame capture and the anti-amp light control in single frame mode.

V2017.08.14.0 WINDOWS X86_X64   qhyccd_V20170814_0.zip
update record:
1.Adjust the QHY5III174 and QHY174 Gain range from 0-48 to 0-480 to get more smooth and fine adustment;
2.For single frame capture mode , fixed a bug that one USB packet transfer error may cause the download hang forever. After fixed this , if there is a usb packet transfer happened, the download will be continous and it will not cause the hang. But since one USB packet is error and this packet data will lost.Part of the rest image will be shift;
3. QHY178M/C single frame capture mode is fixed;
4. We add the AUX image output function in the SDK. It allow the image been transfered to a windows shared memeory and any other software can read the image from this shared memeory.
An known bug in this version:
1.QHY183C may have bug in some roi reoslution in continous video streaming mode.

V2017.05.29.0 WINDOWS X86_X64   qhyccd_V20170529_0.zip
update record:
1.Add the support for QHY128C Camera;
2. Limit the QHY168C and QHY247C offset to 0-30. (Too high offset will cause the background blue);
3.QHY163 USB Traffic is fixed to zero forever for single capture mode,The video streaming mode's USB Traffic still has function.
An known bug in this version:
1.QHY178M/C single image capture is failur in this version. You need to use the V201703 if you are using the QHY178M/C.

V2017.05.28.0 WINDOWS X86_X64   qhyccd_V20170528_0.zip
update record:
1.Fixed the RBI issue of the first image of QHY168C;
2.Fixed the QHY247C image occasionally shift issue.

V2017.05.27.0 WINDOWS X86_X64   qhyccd_V20170527_0.zip
update record:
1.Fixed the first image issue of QHY168C ROI in ASCOM.

V2017.05.24.0 WINDOWS X86_X64   qhyccd_V20170524_0.zip
Update Record:
1.Fixed the QHY168C Color Balance Problem (No much red color);
2.Add the hardware ROI for QHY168C in single capture mode (eg.ASCOM) to accelate the subframe transfer like the focus etc);
3.Fixed the QHY168C image occasionally shift issue;
4.fixed QHY163 hardware ROI bottom black lines in V2015.05.22.0. 5.Fixed the DDRlogger issue in V2015.05.22.1. 5.Fixed the overscan mode software quite after image download;
6.Please note in this version the bayer sequece is X=0 Y=0 in maxium;
7.Image size is set to 5040,3358 in normal mode to avoid the 16pixel white board in right side and 4952,3288 in overscan removed mode.
An known bug is in this version:
1.For QHY168C, if switch from a smaller range to a bigger range subframe in ASCOM. The first frame captured has some exposure problem. The second frame and later will become good. This bug only effect the single capture mode. The video streaming mode like the SharCAP is no this bug.
 
V2017.05.21.1 WINDOWS X86_X64   qhyccd_V20170521_1.zip
Update Record:
1.Fixed the QHY290 high thermal noise in long exposure bug;
Click to read the next