SDK Update History
There are many software using the QHYCCD SDK to connect QHY Camera. When the SDK updated, the software maybe not get updated. You can download this file and copy it to the software folder and replace the old more to get your software has the lastest features of QHYCCD.

Update Method
You can update the qhyccd.dll by replacing the original qhyccd.dll in the application software folder.
SharpCAP
You can replace the 32bit qhyccd.dll in the sharcap folder.
EZCAP_QT
You can replace the 32bit qhyccd.dll in EZCAP_QT folder.
ASCOM
Since the old ascom camera driver installation put the QHYCCD.DLL to the windows/SysWow64 or windows/system32. And the recently ascom camera driver put the QHYCCD.DLL into the programe(x86)/common/ascom/camera.  We recommand to delete the QHYCCD in windows/SysWow64 or windows/system32 and put the new QHYCCD.DLL to the programe(x86)/common/ascom/camera folder.
FireCapture
You can replace the 64bit qhyccd.dll in FireCapture 64bit folder  or 32bit qhyccd.dll in FireCapture 32bit folder.
Genika
Only 64bit Genika is under maintain and support QHYCCD. You can find the Genika in Programme and find the 64bit Genika folder.And replace the qhyccd.dll with the 64bit qhyccd_x64.dll (delete qhyccd.dll, rename the qhyccd_x64.dll to qhyccd.dll)

Version Record   The red is the important bug fix.
V2017.03  WINDOWS X86   qhyccd_V201703.zip
 
V2017.05.21.1 WINDOWS X86_X64   qhyccd_V20170521_1.zip
Update Record:
1.Fixed the QHY290 high thermal noise in long exposure bug;
2.Make the QHY290 and QHY5III290 gain/offset adjustment more smooth,avoid the screen flash happen,Change the gain range to 0-729;
3.Improved the QHY163 Single Frame Capture Mode (For ascom etc) ROI download speed;
4. Change the gain range of QHY163 from 0-58 to 0-580 to get more smooth adjustment;
5.Add the GetQHYCCDSDKVersion function to get the SDK year,month,day,subday version.
 
V2017.05.24.0 WINDOWS X86_X64   qhyccd_V20170524_0.zip
Update Record:
1.Fixed the QHY168C Color Balance Problem (No much red color);
2.Add the hardware ROI for QHY168C in single capture mode (eg.ASCOM) to accelate the subframe transfer like the focus etc);
3.Fixed the QHY168C image occasionally shift issue;
4.fixed QHY163 hardware ROI bottom black lines in V2015.05.22.0. 5.Fixed the DDRlogger issue in V2015.05.22.1. 5.Fixed the overscan mode software quite after image download;
6.Please note in this version the bayer sequece is X=0 Y=0 in maxium;
7.Image size is set to 5040,3358 in normal mode to avoid the 16pixel white board in right side and 4952,3288 in overscan removed mode.
An known bug is in this version:
1.For QHY168C, if switch from a smaller range to a bigger range subframe in ASCOM. The first frame captured has some exposure problem. The second frame and later will become good. This bug only effect the single capture mode. The video streaming mode like the SharCAP is no this bug.
 
V2017.05.27.0 WINDOWS X86_X64   qhyccd_V20170527_0.zip
update record:
1.Fixed the first image issue of QHY168C ROI in ASCOM.
 
V2017.05.28.0 WINDOWS X86_X64   qhyccd_V20170528_0.zip
update record:
1.Fixed the RBI issue of the first image of QHY168C;
2.Fixed the QHY247C image occasionally shift issue.
 
V2017.05.29.0 WINDOWS X86_X64   qhyccd_V20170529_0.zip
update record:
1.Add the support for QHY128C Camera;
2. Limit the QHY168C and QHY247C offset to 0-30. (Too high offset will cause the background blue);
3.QHY163 USB Traffic is fixed to zero forever for single capture mode,The video streaming mode's USB Traffic still has function.
An known bug in this version:
1.QHY178M/C single image capture is failur in this version. You need to use the V201703 if you are using the QHY178M/C.
 
V2017.08.14.0 WINDOWS X86_X64   qhyccd_V20170814_0.zip
update record:
1.Adjust the QHY5III174 and QHY174 Gain range from 0-48 to 0-480 to get more smooth and fine adustment;
2.For single frame capture mode , fixed a bug that one USB packet transfer error may cause the download hang forever. After fixed this , if there is a usb packet transfer happened, the download will be continous and it will not cause the hang. But since one USB packet is error and this packet data will lost.Part of the rest image will be shift;
3. QHY178M/C single frame capture mode is fixed;
4. We add the AUX image output function in the SDK. It allow the image been transfered to a windows shared memeory and any other software can read the image from this shared memeory.
An known bug in this version:
1.QHY183C may have bug in some roi reoslution in continous video streaming mode.
 
V2017.09.10.0 WINDOWS X86_X64   qhyccd_V20170910_0.zip
update record:
1.Fixed the QHY367 image shift issue in single frame when do continous capture;
2.Improved the QHY183 USB transfer when connected to some computer.Fixed the QHY183C roi problem when in some small roi;
3. Improved the QHY178 single frame capture and the anti-amp light control in single frame mode.
 
V2017.09.19.0 WINDOWS X86_X64   qhyccd_V20170919_0.zip
update record:
1.In previous version(20170910) the QHYCCD A series support has some problem since an unexpected modification. Now we fixed it;
2.Add the baisc support for QHY09000A.
 
V2017.09.26.0 WINDOWS X86_X64   qhyccd_V20170926_0.zip
update record:
1.in previous version (20170926), the QHY183C works nice in ASCOM but it has a problem in EZCAP_QT when exposure is longer than some seconds. This version fixed it.
2. Add the full support for QHY09000A.
An known bug in this version:
1.QHY183C have bug under EZCAP_QT when use this verison. When exposure is a little longer the image will has a wrong part on top of it.
 
V2017.10.25.0 WINDOWS X86_X64   qhyccd_V20171025_0.zip
update record:
1.Fixed previous version issue that QHY183 has problem in EZCAP_QT;
2.Force the QHY183C usb traffic to zero when in singleframe mode to minumum the ampglow during readout;
3.Add the support for IMG2PRO;
4. Adjust the usb packet size for QHY21,22,23 and reduce the USB pause dot when CPU busying.
An known bug in this version:
1.QHY247C under USB2.0, when in SharpCAP will be hang. The reason is the USB traffic is too small. We will increase this in next version. This issue does not effect the USB3.0 in SharpCAP, also does not effect the single frame mode like ASCOM / EZCAP_QT;
2. In QHY163 there is some blank lines appear in the full image and in the image with overscan remove mode. We will fix this problem in next version.
 
V2017.11.09.0 WINDOWS X86_X64  qhyccd_V20171109_0.zip
update record:
1.Fixed the overscan remove area define error in the EZCAP_QT for QHY168C,QHY247C issue;
2.Reduce about 12rows for QHY168 fullframe readout image because it is exceed the effeictive image area and the data is a fixed white value . Now it is 5040*3346, before it is 5050*3358. (The overscan remove mode resolution is not changed);
3.Increase the USB traffic limiation in the QHY247C when in USB2.0 mode. To avoid the DDR buffer get full and the image become more and more slow and then hang.
 
V2017.12.21.0 WINDOWS X86_X64  qhyccd_V20171221_0.zip
update record:
1.Fixed the bug that cause the QHY5L-II in live video mode image slightly shifit when in high frame rate(usb bandwidth value is small, eg. >20FPS. This bug affect the driver version from 2017.08.14 to 2017.11.09;
2.Improved the QHY5L-II stability and avoid the hang happen (this bug effect the driver from 2017.05.29 to 2017.11.09;
3.Improved the gain setting range for QHY5L-II-M and QHY5L-II-C. (expanding the actual gain range but reduce the gain steps);
4.Fxied the QHY247C,QHY168C,QHY367C,QHY128C etc the overscan area definitation in EZCAP_QT and the effective image definitation in EZCAP_QT;
5.Fixed the bug that QHY5III series does not suppot CancelExopsing and CancelExposuringAndReadout;
6.Add QHY42 support;
7.Add QHY183M support.
 
V2018.04.13.0 WINDOWS X86_X64 qhyccd_V20180413_0.zip
update record:
1.Added partly support for qhy4040 and qhy294(alpha version);
2.Improved the QHY183C/M,QHY128,QHY163,QHY168,QHY174,QHY1178,QHY224,QHY247,QHY290,QHY367,QHY42 stability and avoid occasionally crash issue in single mode(USB2.0);
3.Fixed the issue about MINICAM5F&PoleMaster crash;
4.Added the offset setup for QHY5L-II-C/M&MINICAM5F&PoleMaster(range is 1~512);
5.Fixed QHY5L-II camera crash issue when adjust exposure time in long expose;
6.Added Amplifier glow control control for QHY42;
7.Fixed  183C/M the problem of insufficient full well at lowest gain;
8.Added DefaultGain  DefaultOffset OutputDataActualBits  OutputDataAlignment in GetQHYCCDParam;
Note:This version of the change requires the latest driver,if your driver version isn't newest,it will popup a dialog to ask you to install the newest driver.
 
V2018.04.24.0 WINDOWS X86_X64 qhyccd_V20180424_0.zip
update record:
1.Fixed SDK version error issue;
2.Added necessary librarys(pssdk.dll&pssdk_x64 and tbb.dll&tbb_x64.dll and ftd2xx.dll&ftd2xx_x64.dll);
Note:This version of the change requires the latest driver,if your driver version isn't newest,it will popup a dialog to ask you to install the newest driver.
 
V2018.05.02.0 WINDOWS X86_X64 qhyccd_V20180502_0.zip
update record:
1.Party cameras have issue with  auto exposure/gain/color balance mode when get single frame,now we has fixed them;
2.Removed dependence of pssdk.dll,but it still contain tbb.dll and ftd2xx.dll;
Note:This version of the change requires the latest driver,if your driver version isn't newest,it will popup a dialog to ask you to install the newest driver.
 